25V-914 Open recall Dec 31, 2025
Braun Industries, Inc.
ELECTRICAL SYSTEM
Braun Industries, Inc. (Braun Ambulances) is recalling certain 2021-2026 Chief XL I, Chief XL III, 2021-2025 Express Plus I, Liberty I, 2025 Express III, Select Chief XL I, and Super Chief I emergency vehicles equipped with a Pran system. The battery isolator may fail, causing a loss of electrical systems such as interior, exterior lighting, and patient support systems.
Risk: A loss of exterior lights can reduce the visibility of the vehicle to other drivers, increasing the risk of a crash. A loss of patient support systems can delay care, increasing the risk of injury.
Remedy: Braun Service or an authorized dealer will update the software, modify wiring, and replace the battery isolator, free of charge. Owner notification letters were mailed January 12, 2026. Owners may contact Braun Ambulances' customer service at 1-877-344-9990. Braun Ambulances number for this recall is 2025-02. The repair is free at any franchised dealer of your brand.
Read the full explainer → 25V-677 Open recall Oct 9, 2025
Braun Industries, Inc.
VEHICLE SPEED CONTROL:CRUISE CONTROL
Braun Industries, Inc. (Braun Ambulances) is recalling certain 2023-2026 Chief XL Type I, Express Plus Type I, Liberty Type I, RMT US Type I, and Select Chief XL Type I ambulances. The brake pedal switch may have been damaged, preventing the cruise control from disengaging when the brake is depressed. As such, these vehicles fail to comply with the requirements of Federal Motor Vehicle Safety Standard numbers 105, "Hydraulic and Electric Brake Systems" and 124, "Accelerator Control Systems."
Risk: Failure to turn off the cruise control may cause unexpected acceleration as the brake is released, increasing the risk of crash.
Remedy: Braun Ambulances will replace the brake switch, free of charge. Owner notification letters were mailed October 27, 2025. Owners may contact Braun Ambulances' customer service at 1-877-344-9990. Braun Ambulances number for this recall is 2025-1. The repair is free at any franchised dealer of your brand.
Read the full explainer → 24V-307 Open recall Apr 30, 2024
Braun Ambulances
ELECTRICAL SYSTEM
Braun Ambulances (Braun Ambulances) is recalling certain 2023-2024 Chief XL I, Chief XL III, Express Plus I, Express III, and Liberty I vehicles. In the event of a short circuit or wiring failure, the firmware in the node may fail to shut off the output pin, resulting in overloaded electrical circuits.
Risk: Overloaded electrical circuits can overheat, increasing the risk of fire.
Remedy: Dealers will update the firmware, free of charge. Owner notification letters were mailed June 17, 2024. Owners may contact Braun Ambulances customer service at 1-877-344-9990. Braun Ambulances number for this recall is 24-003. The repair is free at any franchised dealer of your brand.
Read the full explainer → 24V-082 Open recall Feb 8, 2024
Braun Ambulances
EXTERIOR LIGHTING:LIGHTING CONTROL MODULE
Braun Ambulances (Braun) is recalling certain 2023-2024 Chief XL Type I, Chief XL Type III, Express Plus Type I, Express Type III, and Liberty Type I vehicles. The high contact nodes may cause the module mounted turn signals, backup alarm, brake lights, and rearview camera to turn on intermittently or fail to activate.
Risk: Failure of vital visual systems reduce the vehicle's visibility to other drivers, increasing the risk of a crash.
Remedy: Dealers will replace the node and update the software, free of charge. Owner notification letters were mailed March 26, 2024. Owners may contact Braun customer service at 419-232-7020. Braun's number for this recall is 2024-2. The repair is free at any franchised dealer of your brand.